API 5L X42, X46, X52, X56, X60, X65, X70, X80 PSL2 Pipe Variants in Singapore
API 5L PSL2 Pipes in Singapore is a steel pipe and is commonly used for pipeline transportation systems in the petroleum and natural gas industries. API 5L is suitable for oil and gas transmission, structural application, and mechanical components.
TRIO STEEL IS A LEADING STOCKIST, SUPPLIER AND EXPORTER OF API 5L PSL2 PIPE IN SINGAPORE.
All API 5L X42, X46, X52, X56, X60, X65, X70, X80 PSL2 Pipe Variants in Indonesia are individually covered so that the premium quality of material is retained and there are no damages in the last stages of production.
API 5L comes with imprints relevant to the job information (for example heat number, size, material and part number). This information is also printed along all to whom API 5L is delivered.
Your need for API 5L PSL2 pipes of standard length and diameter pipes and tubing ends here. If you need high strength, high tensile, heavy wall line pipe requirements for deep sour wells, drilling, offshore drilling and production, arctic exploration and production, or you need API 5L PSL2 pipe for natural gas, oil or water transport, then Trio Steel can meet the demands of your company.
PSL2 Steel Pipe is a high yield seamless pipe that is modified to suit offshore structural purposes. It is intended for (but not limited to) use in fixed offshore structures and is designed to operate in the offshore sector.
Trio Steel is already Supplying API 5L PSL 2 Pipes to Singapore. We also further envision to keep stock in Singapore for API 5L PSL 2 Pipes due to the growing demand and need for faster deliveries. We intend to tie-up with local partners with whom we have been working in Singapore for the last 2 Decades. In line with our role as a leading API 5L PSL 2 Pipes manufacturer in Singapore, Trio Steel remains resolute in upholding the highest standards of product quality and service excellence. These partnerships have not only enabled us to understand the unique demands of the Singapore market but also facilitated streamlined operations and improved customer satisfaction.
Trio Steel is also the leading Pipe Suppliers and Pipe Fitting Suppliers of API 5L X42, X46, X52, X56, X60, X65, X70, X80 PSL2 Pipe Variants in Singapore.
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.22 | 0.45 | 1.20 | 0.025 | 0.015 | 0.05 | 0.05 | 0.04 | (g) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam Normalizing |
35,500-65,300 | 245-450 | 60,200-110,200 | 415-760 | 0.93 | – | – | ||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.22 | 0.45 | 1.30/ | 0.025 | 0.015 | 0.05 | 0.05 | 0.04 | (g) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
42,100-71,800 | 290-495 | 60,200-110,200 | 415-760 | 0.93 | – | – | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.22 | 0.45 | 1.30/ | 0.025 | 0.015 | 0.05 | 0.05 | 0.04 | (g) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
46,400-76,100 | 320-525 | 63,100-110,200 | 435-760 | 0.93 | – | – |
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.22 | 0.45 | 1.40/ | 0.025 | 0.015 | (d) | (d) | (d) | (g) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
52,200-76,900 | 360-530 | 66,700-110,200 | 460-760 | 0.93 | – | – | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.22 | 0.45 | 1.40 | 0.025 | 0.015 | (d) | (d) | (d) | (g) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
56,600-79,000 | 390-545 | 71,100-110,200 | 490-760 | 0.93 | – | – | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Metersa
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.12 (e) | 0.45 (e) | 1.60 (e) | 0.025 | 0.015 | (h) | (h) | (h) | (i) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
60,200-81,900 | 415-565 | 75,400-110,200 | 520-760 | 0.93 | 27 | 20 | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.12 (e) | 0.45 (e) | 1.60 (e) | 0.025 | 0.015 | (h) | (h) | (h) | (i) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
65,300-87,000 | 450-600 | 77,600-110,200 | 535-760 | 0.93 | 27 | 20 | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.12 (e) | 0.45 (e) | 1.70 (e) | 0.025 | 0.015 | (h) | (h) | (h) | (i) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
70,300-92,100 | 485-635 | 82,700-110,200 | 570-760 | 0.93 | 27 | 20 | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
API 5L Pipe
API 5L Line Pipe
API 5L Supplier
API 5L Pipe Price Know more
Nominal Pipe Size for
API 5L X80 PSL2 LSAW Steel Pipes: 2″ to 28″ O.D.
Wall Thickness – Schedule 10 through 160, STD, XS, XXS
Chemical Properties of API 5L X80 PSL2 LSAW Steel Pipes |
||||||||
Mass fraction, based upon heat and product analysis a | ||||||||
C | Si | Mn | P | S | V | Nb | Ti | Other |
max.b | max | max.b | max. | max. | max. | max. | max. | |
LSAW PIPE – API 5L X80 PSL2 | ||||||||
0.22 | 0.45 | 1.30 | 0.025 | 0.015 | 0.05 | 0.05 | 0.04 | g |
Notes:
- 0.50% maximum for cooper; 0.50% maximum for nickel; 0.50% maximum for chroium and 0.15% maximum for molybdenum. For grades up to and including XS2, Cu, Cr and Ni shall not be added intentionally.
- For esach reduction of 0.01% below the specified maximum concentration of carbon, an increase of 0.05% above the specified maximum concentration for manganese is permissible, up to a maximum of 1.65% for grades>= X52; upto a maximum of 1.75% for grades>X52, but
- Unlcess otherwise agreed, the sum of the niobium and vanadium contents shall be <=0.06%.
- The sum of the niboium, vanadium and titanium concentrations shall be <=0.15%.
- Unless otherwise agreed.
- Unless otherwise agrees, the sum of niboium, vanadium and titanium concentrations shall be <=0.15%.
- Unless otherwie agreed, 0.50% maximum ofr copper, 0.30% maximum for nickel, 0.30% maximum for chromiumand 0.15% maximum for molybdenum.
- Unless otherwise agreed, the sum of niboium, vanadium and titanium concentrations shall be <=0.15%.
- For pipe with diameter<219.10mm(8.625″), the maximum yield strength shall be <=495Mps(71,800 psi).
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
70,300-92,100 | 485-635 | 95000-125000 | 655-862 | 0.93 | 27 | 20 | ||||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Note:
- 0.50% maximum for copper, 0.50% maximum for nickel, 0.50% maximum for chromium, and 0.15% maximum for molybdenum.
- For each reduction of 0.01% below the specified maximum concetration for carbon, an increase of 0.05% above the specified maximum concentration for manganese is permissible, up to a maximum of 1.65%
- Unless otherwise agreed, the sum of the niobium and vanadium contents shall be ≤0.06%.
- The sum of the niobium ,vanadium and titanium concentratons shall be ≤0.06%.
- Unless otheriwse agreed.
- Unless otherwise agreed, the sum of niobium, vanadium and titanium concentrations shall be ≤ 0.15%
API 5L Pipe
API 5L Line Pipe
API 5L Supplier
API 5L Pipe Price Know more
Nominal Pipe Size for
API 5L X80 PSL 2 Seamless Steel Pipes India Special Steels : 2″ to 28″ O.D.
Wall Thickness – Schedule 10 through 160, STD, XS, XXS
Chemical Properties of API 5L X80 PSL2 Seamless Steel Pipes |
||||||||
Mass fraction, based upon heat and product analysis a | ||||||||
C | Si | Mn | P | S | V | Nb | Ti | Other |
max.b | max | max.b | max. | max. | max. | max. | max. | |
SEAMLESS PIPE – API 5L X80 PSL2 | ||||||||
0.22 | 0.45 | 1.30 | 0.025 | 0.015 | 0.05 | 0.05 | 0.04 | g |
Notes:
- 0.50% maximum for cooper; 0.50% maximum for nickel; 0.50% maximum for chroium and 0.15% maximum for molybdenum. For grades up to and including XS2, Cu, Cr and Ni shall not be added intentionally.
- For esach reduction of 0.01% below the specified maximum concentration of carbon, an increase of 0.05% above the specified maximum concentration for manganese is permissible, up to a maximum of 1.65% for grades>= X52; upto a maximum of 1.75% for grades>X52, but
- Unlcess otherwise agreed, the sum of the niobium and vanadium contents shall be <=0.06%.
- The sum of the niboium, vanadium and titanium concentrations shall be <=0.15%.
- Unless otherwise agreed.
- Unless otherwise agrees, the sum of niboium, vanadium and titanium concentrations shall be <=0.15%.
- Unless otherwie agreed, 0.50% maximum ofr copper, 0.30% maximum for nickel, 0.30% maximum for chromiumand 0.15% maximum for molybdenum.
- Unless otherwise agreed, the sum of niboium, vanadium and titanium concentrations shall be <=0.15%.
- For pipe with diameter<219.10mm(8.625″), the maximum yield strength shall be <=495Mps(71,800 psi).
MECHANICAL REQUIREMENT | ||||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing | ||
70,300-92,100 | 485-635 | 95000-125000 | 655-862 | 0.93 | 27 | 20 | ||||
Note:
- 0.50% maximum for copper, 0.50% maximum for nickel, 0.50% maximum for chromium, and 0.15% maximum for molybdenum.
- For each reduction of 0.01% below the specified maximum concetration for carbon, an increase of 0.05% above the specified maximum concentration for manganese is permissible, up to a maximum of 1.65%
- Unless otherwise agreed, the sum of the niobium and vanadium contents shall be ≤0.06%.
- The sum of the niobium ,vanadium and titanium concentratons shall be ≤0.06%.
- Unless otheriwse agreed.
- Unless otherwise agreed, the sum of niobium, vanadium and titanium concentrations shall be ≤ 0.15%
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all
the products.
CHEMICAL COMPOSITION | ||||||||||
C | Si | MN | P | S | V | Nb | Ti | Other | Carbon Equivalent | |
Max (b) | Max | Max (b) | Max | Max | Max | Max | Max | % maximum | ||
CE(IIW) | CE(Pcm) | |||||||||
0.12 (e) | 0.45 (e) | 1.70 (e) | 0.025 | 0.015 | (h) | (h) | (h) | (i) | 0.43 | 0.25 |
MECHANICAL REQUIREMENT | ||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing |
100,500-121,800 | 690-840 | 110,200-143,550 | 760-990 | 0.93 | 27 | 20 | ||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |
Applicable codes and standards API 5L, 45th Edition / ISO 3183 Specification for line pipe – technical delivery conditions.
Size: ¼” to 36”
Wall Thickness: SCH 10 to 160, STD, XS, XXS
Length: up to 12 Meters
*Additional testing requirements met*: NACE MR
0175,NACE TM0177,NACE TM0284,HIC TEST, SSC TEST, H2 SERVICE,IBR, ECT in all the products.
CHEMICAL COMPOSITION | ||||||||||
Grade | C | Mn | P | S | Si | Nb+Ti | Ni+Cr+Cu | Cr+Mn+Mo | ||
X120 | 0.06 | 1.9 | 0.004 | 0.004 | 0.25 | ≤0.08 | ≤1.5 | ≤3 |
MECHANICAL REQUIREMENT | ||||||||
Tensile Requirements on Pipe body of welded pipes | Ratio | Elongation | CVN Absorbed Energy | Heat Treatment | ||||
Yield Strength (R10.5) | Tensile Strength (R) | R 10.5/ R | % | 0 degree celsius | ||||
PSI | Mpa | PSI | Mpa | Max | Minimum | Min J | Min ft. lb | Wield Seam & HAZ Normalizing |
120,350-152,350 | 830-1050 | 132,675-166,025 | 915-1145 | 0.93 | 27 | 20 | ||
IMPACT TEST |
|
AVG ABSORBED ENERGY | IND. ABSORBED ENERGY |
MIN (JOULES) | MIN (JOULES) |
27 | 20 |